WingLock™ + TwinLock™Valve Technology: A Closer Look
Therm-a-Rest TeamHere at Therm-a-Rest we are stoked for you to experience the new WingLock™ and TwinLock™ valves. So, we sat down with two Therm-a-Rest design engineers to get a behind the scenes technical perspective on the new valves and how they came to be. If you want to find information about the valves that you won’t find anywhere else, this is the place.
Who are you and what do you do for Therm-a-Rest?
Mikk: I'm Mikk Kaschko. I am a design engineer, which means designing mostly plastic parts for Therm-a-Rest or designing with our fabrics and foams and integrating all those into the design process.
Mack: I'm Mack Hauff, I'm the product development manager and a part-time design engineer. So, part of the time I do the same thing as Mikk, the rest of the time I do too much to list. Alright, let's talk about those WingLock™ and TwinLock™ valves. I figured we would start at the very beginning, why did Therm-a-Rest decide to retire the classic valve and develop a new one? Was there anything wrong with the classic valve?
Mikk: No. I mean it's a, it's a bomber design and we are still using it on all of our small volume products, like pillows and seats because they don't require moving a lot of air in and out. It has plenty flow rate to do that. The main couple of reasons behind the project was increasing the flow rate, and improving the interaction between the users and the pad.
What do you mean when you say "interaction?"
Mikk: I'm talking about check valves or other things to help get that air into the mattress and keep it there without them having to do anything separate. With the classic valve, you can put your tongue on the valve and prevent most of the air from escaping.... but then you're like, taking a breath with your tongue on the valve and it's this multi-step process… and then your buddy talks to and you're like, "what?"
Oh yeah, I used to work in Repairs, so I've seen some dog aftermath.
Mikk: We also wanted a good interface for mouth inflation because so many customers fill their pads this way. We have mattresses that are 30, 40 years old that come into repairs and are irreparable for whatever reason. We have cut them open and you can see that there's no degradation in the foam because of mouth inflation, so we needed a mouth interface ready for hundreds of uses. Some of the flat valves are kind of awkward because you can't hold them up to your face while you inflate the mattress very easily.
Mack: It's the macro versus micro movements. Twisting it's a natural, micro movement that you can do pretty easily with your gloves on in cold conditions. Some competitors' valves you have to grab onto something and rip it. It's not a natural movement as opposed to just twisting things. So, that was one of the main objectives, to keep it something that you can do eyes closed or in a dark tent—that didn't require a lot of effort or thought put into it.
From those core objectives, how did we decide to design two valves, the WingLock™ and also the TwinLock™? Was that the initial plan or was there a split?
Mack: There was a split at some point, not the initial plan to do that. We understood that this was going on every pad, and it worked well for, you know, all the air pads that are three inches and under. But the same year that we are launching this, we are also launching four-inch air pads. We realized that we were making things faster but it still wasn't fast enough for our higher volume pads. We needed a faster way to dump the air out, especially for the higher volume pads. So halfway through we knew we needed to come up with a specific valve for the extra big pads, and that became the TwinLock™.
When did this project kick off? How long has it been?
Mikk: Like mid 2017 I think, right?
Mack: Yes, and no. A while before that people were starting to tell us that we were too slow and someone on the team just plain said, "we need to make a better valve." This is probably going to sound bad, but we floated the idea of just putting a band-aid on it where we just made the classic valve 30% bigger, so it would've looked identical but larger. Ultimately, we were like, "that's not us, we can't just do that. It's not enough and not the way that we do things." We decided to do it right, and that meant coming up with something brand new.
Can you walk us through a day in the life of a Therm-a-Rest design engineer working on the valve project? In the thick of the project, what was your work like?
Mack:
Was there one challenge in particular that that stuck out to you during the project?
Mikk: One of the more memorable challenges was the instructions.
Mack: Oh yeah! Yeah, yeah.
Mikk: When we started with the WingLock™, it looked drastically different than it does now. It was much slimmer, but it wasn't visually notifying our users how to work it. You would twist the wings still, but they were just these little triangles on top, they blended in so nicely.
Mack: It was so sleek and sexy.
After all that, when did you know you're going to have a great product for the market?
Mikk: The first time that I knew the TwinLock™ was going to be awesome was when I had a MondoKing™ 3D that I made with these 3D printed valves that I glued in so they didn't leak. I took it to a week-long family visit in Detroit, Michigan and slept on it for eight nights in a row and I was deflating it every morning to make room in the house. Just how fast it was to deflate the pad with the new valve and how easy it was to inflate it with the pump sack I had with me... It felt so far beyond the 2019 MondoKing™. I was recommending all my friends to wait until next season to buy a pad, it's just that good.
You're not supposed to do that.
There are a lot of sleeping pads on the market and some worthy competition; a lot of great designs out there. From a design engineering perspective how do the WingLock™ and the TwinLock™ valves stand out in comparison to the competition?
Mack: I think ours are the most reliable. The WingLock uses two compressed O-rings and the O-rings are protected. Valves with exposed sealing surfaces aren't as protected. You get dirt on the pad, and when you close the valve the dirt is going to get in there and interact with the sealing surfaces, causing potential leaks. We believe in compressed O-rings. We like the fact that they are shielded from the outside environment. Again, we rely on simple twisting actions whereas other valves you have to pinch and pull up, or put your finger into the bleed. It’s just not as easy, especially in the cold weather with gloves on, or in a crowded tent. I think ours are more intuitive, simpler, easier to use.
So, if you're in a three-person tent, stuck in the middle, you can still reach over and let little air out if you happen to over-inflate...
Mack: Yeah, exactly. You don't have to roll off or elbow your neighbor. When you're "backcountry tired" you need things to be simple otherwise you're not going to do them. You'll be like, "fine, I'm just gonna try to sleep." Then you just sleep restlessly for the rest of the night, and your body isn't properly rested for the next day. That's a poor user experience.
Mikk: To add, in choosing our O-rings we went through three different materials to find one that maintained its same performance at -40F and 140F. It barely changes the feel of how the valve works at extreme cold temperatures or hot temperatures. That's a big one for me at least. Being replaceable/repairable is another big one. Most, if not all, of our major competitors can't repair a valve if something fails. And, we talked about this earlier, but mouth inflation is easier with a valve off the surface of the pad. Trying to hold a flat valve against your mouth can be really awkward, especially once the mattress starts to get full. When it's not full you can kind of grab it and manhandle it and get a good purchase. Once it gets full, there's nothing to grab onto anymore.
We were trying initially to design the fastest inflate and the fastest deflate, that was obviously an early goal. At a certain point in our testing we found that this one competitor had this really big hole in their mattress when you open their valve, and it took one less second to deflate their pad versus one of our pads with the TwinLock™. The design compromise to get to that was immense. Would it be worth it? We decided no, because you can get 95% of the way there with a much more robust design that meets some important core objectives like repair-ability and ease of use, etc.
Mack: To drill down just a little bit further on the replaceability, if the valve delaminates you throw the whole pad away, with ours you could save yourself $200 by buying a $10 replacement part, which is pretty rad.
Mikk: And it's also not going into the landfill! I would say that's pretty important, especially to a lot of our customers.
We’ve been talking about faster flow rates. One of the more remarkable claims Therm-a-Rest has made about the WingLock™ is that they inflate your pad 3x faster than the classic valves. Some early reviews came in that contradicted this claim. Yet, hearing you guys talk of the rigorous testing and development it seems a little crazy that we would just say that if we were untrue. Can you provide some perspective on the matter?
Mikk: We certainly tested it, and I think there's a little bit of miscommunication going on. I checked our website, and right now it says, "3x faster flow rate." The flow rate through the valve is 3x faster at an average person's breath. Typically, when somebody is inflating a pad they have a certain amount of pressure and flow rate that they can generate with their lungs.
Do you know what that pressure is?
Mikk: It's about 5 inches of water. Which is about 0.2 pounds per square inch (PSI). This will give them a momentary flow rate of 6.5 standard cubic feet per minute (SCFM) through the WingLock™ valve. Through the classic valve, they would only achieve 2.2 SCFM. 2.2 to 6.5 is 295% change, or a 3x faster flow rate.
Mack: But the volume that you need to blow in is still the same. It's just easier. Perhaps that would have been a better way to say it, "3x easier," because 3x faster flow rate kind of translates into 3x less effort. You're expending less energy from your lungs, but it's still the same amount of volume that needs to go into the pad.
Mikk: What units do you measure easier in though? We're engineers, we like mathematically measurable things.
Thanks for clearing that up. To round that out, if you were out in the field with the new valves, how would you achieve the fastest inflation? What would you do or use?
Mack: I would personally use the
Any final thoughts for our readers? Like maybe read the instructions?